Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Rev. bras. cir. cardiovasc ; 37(3): 301-305, May-June 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1376539

ABSTRACT

ABSTRACT Introduction: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Some prostheses available in the market cannot be fractured. In an ex vivo test, the possibility of ring fracture of aortic valve bioprostheses produced in Brazil when submitted to radial force application using a high-pressure non-compliant balloon was evaluated. Methods: One unit of each aortic valve bioprosthesis model, sizes 19 and 21 mm, produced by Brazilian companies (Braile Biomédica, Cardioprótese, and Labcor), was used. In the experiment, a non-compliant high-pressure balloon (Atlas®-Gold), 1 mm larger than the external diameter of the prosthesis, was positioned inside the valve annulus and inflated gradually aiming to fracture the prosthesis. Fracture pressures and photographic and radiological images of the prostheses before and after test were recorded. Results: All prostheses were fractured. In the models with metal ring, the fracture pressures were between 23 and 25 atm. In the other prostheses, the rupture occurred between 10 and 13 atm. No deformations in the structure were observed, which could potentially damage the aortic root. Conclusion: All the Brazilian prostheses evaluated were fractured, although the presence of a metal ring in the prosthesis framework increases the pressure required for fracture. The information obtained helps in the planning of valve-in-valve procedures in patients with aortic valve bioprostheses.

2.
Rev. bras. cir. cardiovasc ; 35(2): 127-133, 2020. tab, graf
Article in English | LILACS | ID: biblio-1101470

ABSTRACT

Abstract Objective: To evaluate the hemodynamic performance (i.e., gradients and paravalvular leakage [PVL]) of the new and experimental Braile Inovare® Proseal. Additionally, we aimed to assess pre and postoperatively the aortic annulus and the transcatheter prosthesis using multislice computed tomography (MSCT). Methods: Patients were selected by a multidisciplinary heart team and referred for transcatheter aortic valve replacement (TAVR). MSCT was performed before and after surgery. Measurements of the aortic valve and prosthesis were conducted and correlated with the valve gradient and residual PVL. Results: Twenty-one patients were selected for the protocol. Patients had a mean age of 79 years and 38% of them were of female sex. The mean EuroSCORE II value was 12.5%±10.8. Mean gradient was reduced from 45.8±11.04 mmHg to 5.59±2.61 mmHg and there were no instances of PVL worse than mild. There were no cases of coronary obstruction or procedural death. Circularity was present in all prostheses evaluated. Circularity indexes for the prostheses were: inflow 0.05±0.03, middle third 0.04±0.02, and outflow 0.04±0.02 (P=0.08). The mean distance between the prosthesis and the left and right coronary ostia were 14.8 mm±3.3 and 17.3 mm±3, respectively. Oversizing was appropriate with a mean of 22.14%±6%. Conclusion: Braile Inovare® Proseal transcatheter device has demonstrated low gradients with low rates of PVL. Oversizing by annular measurements was adequate. MSCT was adequate to evaluate device sizing and has demonstrated preserved expansibility and circularity in the evaluated cases.


Subject(s)
Humans , Male , Female , Aged , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve , Aortic Valve Stenosis , Prosthesis Design , Stroke Volume , Cardiac Catheterization , Ventricular Function, Left , Treatment Outcome , Multidetector Computed Tomography , Hemodynamics
3.
Rev. bras. cir. cardiovasc ; 28(2): 217-223, abr.-jun. 2013. ilus
Article in Portuguese | LILACS | ID: lil-682432

ABSTRACT

OBJETIVO: A insuficiência cardíaca é uma das causas mais comuns de internação. Dispositivos para assistência circulatória crônica foram testados e, em sua maioria, são de alta complexidade. O objetivo deste estudo é a descrição de uma endoprótese contrátil com capacidade de pulsação crônica no interior da aorta descendente, de maneira semelhante à produzida pelo balão intra-aórtico. MÉTODOS: Endopróteses pulsáteis compostas de níquel-titânio foram posicionadas de forma a envolver tubos de látex, simulando a aorta. Diferentes correntes elétricas foram aplicadas a unidades ligadas em série, de modo a causar contração da estrutura e deslocamento de uma coluna líquida. Foram realizadas duas sequências de testes: a primeira com duas gaiolas metálicas e a segunda com cinco gaiolas. Na primeira sequência de testes, aplicou-se tensão de 16,3 volts e corrente de 5 amperes e, na segunda sequência, tensão de 15 volts e corrente de 7 amperes. RESULTADOS: Na primeira sequência de testes, obteve-se o efeito pulsátil dos 2 stents, havendo contração do tubo e deslocamento da coluna d'água suficientes para validar o efeito pulsátil da endoprótese. As duas estruturas ejetaram um volume de 2,6 mL por ciclo, com uma variação de 29 mm na altura da coluna de água, equivalente a 8% de contração durante a pulsação. Na segunda sequência, conseguiu-se uma variação de 7,4 mL por ciclo. CONCLUSÃO: Os resultados obtidos comprovam a contratilidade da endoprótese pulsátil ativada pela aplicação de corrente elétrica. Continuidade do estudo e aperfeiçoamento do material se fazem necessários para obtenção de modelo mais eficiente do ponto de vista energético e com maior pulsação, para permitir volumes de ejeção comparáveis aos de balões intra-aórticos.


OBJECTIVE: Heart failure is currently one of the most common hospitalization causes. Several chronic circulatory assist devices have been tested and are highly complex. The objective is the description of a pulsatile endoprosthesis capable of applying a chronic pulse within the descending aorta, similar to that produced by intra-aortic balloon. METHODS: Pulsatile stents composed of nickel-titanium were built and positioned to engage latex tubes simulating the aorta. Different electric currents were applied to units connected in series in order to cause structure contraction and displacement of a liquid column. There were two sequence tests: first composed of two metallic cages and the second composed of five cages. At first sequence tests was applied a voltage of 16.3 volts and a current of 5 amperes. In the second, voltage of 15 volts and current of 07 amperes. RESULTS: In the first sequence was obtained the pulsatile effect of stent, with contraction of the tube and displacement of the water column sufficient to validate the pulsating effect of the endoprosthesis. The two structures ejected a volume of 2.6 ml per cycle, with a range of 29 mm in height of the column of water equivalent to 8% shrinkage during the pulse. In the second sequence, it reachead a variation of 7.4 mL per cycle. CONCLUSION: The results obtained confirm the stent pulsatile contractility activated by electrical current. The continuity of the study and material improvement are necessary to obtain more efficient model from the point of view of energy and pulse, to allow ejection volumes comparable with the intra-aortic balloons.


Subject(s)
Humans , Heart-Assist Devices , Heart Failure/therapy , Pulsatile Flow , Prosthesis Design/methods , Stents , Aorta , Heart Ventricles , Medical Illustration , Nickel/therapeutic use , Reproducibility of Results , Titanium/therapeutic use
4.
Rev. bras. cir. cardiovasc ; 27(3): 355-361, jul.-set. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-660805

ABSTRACT

INTRODUÇÃO: A reoperação para substituição de biopróteses aórticas com disfunção é procedimento que envolve considerável risco. Em alguns casos, a mortalidade é elevada e pode contraindicar o procedimento. O implante minimamente invasivo "valve-in-valve" transcateter de valva aórtica parece ser uma alternativa, reduzindo morbimortalidade. O objetivo deste estudo foi avaliar esses implantes utilizando a prótese Braile Inovare. MÉTODOS: A prótese Braile Inovare, transcateter, balão expansível foi utilizada em 14 casos. Euroscore médio foi de 42,9%. Todos os pacientes eram portadores de dupla disfunção de bioprótese aórtica. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Por meio de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência. Foram realizados controles clínicos e ecocardiográficos seriados. O seguimento variou de 1 a 30 meses. RESULTADOS: A correta liberação protética foi possível em todos os casos. Não ocorreu conversão. Não houve mortalidade operatória. A mortalidade em 30 dias foi de 14,3% (dois casos). A fração de ejeção apresentou aumento significativo após o 7º pós-operatório e o gradiente aórtico apresentou redução significativa. A insuficiência aórtica residual não esteve presente. Não ocorreu complicação vascular periférica ou bloqueio atrioventricular total. CONCLUSÕES: O implante "valve-in-valve" de valva aórtica transcateter em biopróteses com disfunção é um procedimento seguro e com morbimortalidade baixa. Essa possibilidade poderá alterar a indicação de seleção de prótese no procedimento inicial, favorecendo próteses biológicas.


OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure. Minimally invasive transcatheter aortic "valve-in-valve" implant appears to be an alternative, reducing morbidity and mortality. The objective is to evaluate aortic valve-in-valve procedure using Braile Inovare prosthesis. METHODS: The Braile Inovare prosthesis, transcatheter, expandable balloon, was used in 14 cases. Average EuroSCORE was 42.9%. All patients had double aortic bioprosthesis dysfunction. Procedures were performed in a surgical hybrid environment under echocardiographic and fluoroscopic guidance. Using left minithoracotomy prostheses were implanted through the ventricular apex under high-frequency ventricular pacing. Serial clinical and echocardiographic controls were performed. Follow-up ranged 1-30 months. RESULTS: Correct prosthetic deployment was obtained in all cases. There was no conversion. There was no operative mortality. The 30-day mortality was 14.3% (two cases). Ejection fraction increased significantly after the 7th postoperative day. Aortic gradient significantly reduced. The residual aortic regurgitation was not present. There were no vascular complications or complete atrioventricular block. CONCLUSION: The transcatheter "valve-in-valve" procedure for bioprosthesis dysfunction is safe with low morbidity. This possibility may change prosthesis choice during the first aortic valve replacement, favoring bioprostheses.


Subject(s)
Aged , Female , Humans , Male , Aortic Valve Stenosis/surgery , Bioprosthesis , Cardiac Catheterization/methods , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/mortality , Cardiac Catheterization/mortality , Heart Valve Prosthesis Implantation/mortality , Kaplan-Meier Estimate , Reproducibility of Results , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
5.
Rev. bras. cir. cardiovasc ; 27(3): 419-428, jul.-set. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-660814

ABSTRACT

INTRODUÇÃO: As biopróteses valvares cardíacas estão relacionadas a eventos tromboembólicos, infecciosos e degenerativos. Seu desgaste é atribuído principalmente à desnaturação do colágeno. O glutaraldeído, método predominante de preservação de biopróteses, favorece o processo de calcificação e limita sua durabilidade. Diversas técnicas tentam conter o processo degenerativo das biopróteses. OBJETIVO: Avaliar o processo de calcificação, in vivo, de heteroenxertos pulmonares valvados, preservados em meio não-aldeídico (L-Hydro®). MÉTODOS: Dezessete carneiros foram submetidos à substituição do tronco da artéria pulmonar por enxerto tubular valvado de pericárdio bovino. Os animais foram distribuídos em dois grupos: Grupo L-Hydro® (teste / n=14) e Grupo Glutaraldeído (controle /n=3). Cerca de 150 dias pós-implante os animais foram sacrificados, necropsiados e as próteses submetidas a estudo anatomopatológico, avaliação radiológica e dosagem do cálcio por espectrofotometria de absorção atômica. A análise estatística foi obtida por meio dos testes exato de Fisher, T de Student ou Mann-Whitney (significância: 5%). RESULTADOS: A avaliação radiológica, macroscopia, microscopia e dosagem de cálcio por espectrofotometria de absorção atômica demonstraram maior calcificação nas próteses do Grupo Glutaraldeído, quando comparadas às próteses do Grupo L-Hydro® (P=0,001). Sete animais do Grupo L-Hydro® (50%) apresentaram aderência das cúspides à parede do tubo (P=0,228). CONCLUSÕES: As próteses preservadas em L-Hydro® demonstraram-se mais resistentes à calcificação, quando comparadas às preservadas em glutaraldeído.


INTRODUCTION: The cardiac bioprostheses are related to thromboembolic events, infectious and degenerative diseases. Wear is mainly attributed to the denaturation of collagen. Glutaraldehyde, the predominant method of preservation of bioprostheses, favors the calcification process and limits their durability. Several techniques try to contain the degenerative process of bioprostheses. OBJECTIVES: To evaluate the process of calcification in vivo pulmonary valve heterografts preserved in non-aldehydic (L-Hydro®). METHODS: Seventeen sheep underwent replacement of the pulmonary artery valved tubular grafts of bovine pericardium. The animals were divided into two groups: Group L-Hydro® (test / n = 14) and Group Glutaraldehyde (control / n = 3). About 150 days after implantation the animals were sacrificed, necropsied and implants subjected to a pathological study, radiological evaluation and measurement of calcium by atomic absorption spectrophotometry. Statistical analysis was obtained through the Fisher's exact test, Student's t or Mann-Whitney test (significance: 5%). RESULTS: The radiological evaluation, the macroscopic and microscopic measurement of serum calcium by atomic absorption spectrophotometry showed increased calcification of the prosthetic group Glutaraldehyde, when compared to denture-HydroR Group L (P = 0.001). Seven animals in Group L-Hydro® (50%) had adherence of the leaflets to the wall of the tube (P = 0.228). CONCLUSIONS: Prostheses preserved in L-Hydro® were more resistant to calcification when compared with glutaraldehyde preserved.


Subject(s)
Animals , Bioprosthesis , Calcinosis/physiopathology , Glutaral , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Pulmonary Artery/surgery , Pulmonary Valve/surgery , Calcinosis/pathology , Calcium/blood , Prosthesis Design , Prosthesis Failure , Pulmonary Artery/pathology , Pulmonary Artery , Sheep , Spectrophotometry, Atomic , Time Factors
6.
Rev. bras. cir. cardiovasc ; 26(3): 338-347, jul.-set. 2011.
Article in Portuguese | LILACS | ID: lil-624514

ABSTRACT

OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, contraindicando o procedimento. O implante minimamente invasivo transcateter de valva aórtica parece ser alternativa, reduzindo a morbimortalidade. A avaliação dos resultados clínicos, segurança e eficácia do procedimento são o objetivo desse estudo. MÉTODOS: Uma prótese transcateter, balão expansível foi utilizada em 33 casos de alto risco. EuroScore médio foi de 39,30% e STS score de 30,28%. Oito pacientes apresentavam disfunção de bioprótese e o restante, estenose aórtica calcificada. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Através de minitoracotomia esquerda, as próteses foram implantadas pelo ápice ventricular, sob estimulação de alta frequência ou choque hemorrágico. Foram realizados controles clínicos e ecocardiográficos. RESULTADOS: A correta liberação da prótese foi possível em 30 casos. Três conversões ocorreram. A mortalidade operatória foi de um caso e a mortalidade em 30 dias, 18,18%. O gradiente médio reduziu de 43,58 para 10,54 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual esteve presente em 30,30% dos pacientes. Ocorreu uma complicação vascular periférica e um caso de bloqueio atrioventricular total. Um paciente apresentou acidente vascular cerebral. A mortalidade em 30 dias foi de 18,18%. CONCLUSÃO: O implante transapical de valva aórtica transcateter é procedimento seguro e com resultados de médio prazo satisfatórios. São necessários estudos de longo prazo com maior poder amostral no intuito de determinar resultado hemodinâmico, qualidade de vida e sobrevida em longo prazo.


OBJECTIVE: Aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such risk can justify contraindication. Minimally invasive transcatheter aortic valve implantation has emerged as an alternative, with lower morbidity and mortality. The aim of this study was clinical, safety and efficacy assessment. METHODS: Thirty-three high risk patients underwent transcatheter balloon expandable aortic valve implantation. Mean Logistic EuroScore risk was 39.30% and STS score 30.28%. Eight patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis were implanted trough the ventricular apex under rapid ventricular pacing or hemorrhagic shock. Echocardiographic and angiographic controls were performed. RESULTS: Implant was feasible in 30 cases. Three conversions occured. There was only one case of operative death. Median transvalvular aortic gradient reduced from 43.58 mmHg to 10.54 mmHg. Left ventricular function improved in the first 7 postoperative days. Paravalvular aortic regurgitation was mild and present in 30.30%. One case presented major vascular complication and another one permanent pacemaker implant. One major stroke case occurred. Overall 30-day mortality was 18.18%. CONCLUSION: The transapical implantation of catheter mounted bioprosthesis is a safe procedure with acceptable midterm results. Long term follow-up with increased sample power is mandatory in order to access hemodynamic, life quality and survival.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Calcinosis/surgery , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/physiopathology , Brazil , Calcinosis/physiopathology , Feasibility Studies , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/mortality , Kaplan-Meier Estimate , Risk Assessment/methods , Treatment Outcome
7.
Rev. bras. cir. cardiovasc ; 26(3): 348-354, jul.-set. 2011.
Article in Portuguese | LILACS | ID: lil-624515

ABSTRACT

INTRODUÇÃO: Nos pacientes portadores de cardiopatias congênitas que foram submetidos à valvotomia pulmonar ou cirurgias de ampliação com o uso do anel da válvula pulmonar, a insuficiência ou estenose pulmonar residual pode acarretar falência cardíaca direita com deterioração clínica. Essas crianças necessitam de múltiplas intervenções ao longo de suas vidas, que impõem uma elevada taxa de morbidade e mortalidade. OBJETIVO: Desenvolvimento de uma técnica menos invasiva para implante de uma prótese valvada através do ventrículo direito. MÉTODOS: A prótese valvada consiste em um anel metálico construído com nitinol autoexpansível, revestida de poliéster, onde três cúspides de pericárdio bovino foram montadas. Doze porcos foram utilizados para a realização dos implantes. Foi realizado controle ecocardiográfico imediatamente após o implante e com uma, quatro, oito e 12 semanas. RESULTADOS: Um animal apresentou refluxo de grau moderado a importante e outros três refluxo de grau leve. Os gradientes transvalvares medidos antes do implante variavam entre 3 a 6 mmHg, sendo que, logo após o implante, houve aumento dos gradientes que variaram de 7 a 45 mmHg. Houve queda desses gradientes, sendo que em apenas quatro dos 12 animais os gradientes estavam acima de 20 mmHg. Em seis animais, ocorreu a formação de trombo na prótese, sendo esta a complicação mais frequente. CONCLUSÃO: Esses achados evidenciam a necessidade da realização de estudos com a utilização de anticoagulantes e ou antiagregantes plaquetários na tentativa de diminuir esse evento. O estudo pretende apresentar subsídios para o início do emprego de próteses valvares que poderiam ser implantadas através de técnicas menos invasivas.


INTRODUCTION: Patients with congenital heart disease who underwent pulmonary valvotomy or surgery to open the pulmonary valve ring are prone to develop residual pulmonary insufficiency or stenosis that may lead to right heart failure with clinical deterioration. These children require multiple interventions throughout their lives, which impose a high rate of morbidity and mortality. OBJECTIVE: To develop a less invasive technique for implantation of a valved prosthesis through the right ventricle. METHODS: The valved prosthesis consists of an auto expanding metal stent built with nitinol, surrounded with polyester, where the three leaflets of bovine pericardium were mounted. Twelve pigs were used to perform the implants. Echocardiographic control was performed immediately after implantation and one, four, eight and 12 weeks. RESULTS: One animal showed reflux of moderate to severe and three mild reflux. Transvalvular gradients measured before implantation ranged from 3 to 6 mmHg and that soon after the implant was increased, ranging from 7 to 45 mmHg. There was a decrease in these gradients during follow up and in only four of the twelve animals the gradients were above 20 mmHg. Thrombus formation occurred in the prosthesis of six animals, and this was the most frequent complication. CONCLUSION: These findings highlight the need for studies with the use of anticoagulants and antiplatelet, an attempt to reduce this event. The study aims to contribute for the start of the use of prosthetic heart valves that could be implanted through minimally invasive techniques without the use of cardiopulmonary bypass.


Subject(s)
Animals , Male , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis/adverse effects , Heart Ventricles/surgery , Prosthesis Design/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Ventricles , Swine
8.
Clinics ; 66(12): 2049-2053, 2011. tab
Article in English | LILACS | ID: lil-609001

ABSTRACT

OBJECTIVES: Patients with coronary artery disease and left ventricular dysfunction have high mortality when kept in clinical treatment. Coronary artery bypass grafting can improve survival and the quality of life. Recently, revascularization without cardiopulmonary bypass has been presented as a viable alternative. The aim of this study is to compare patients with left ventricular ejection fractions of less than 20 percent who underwent coronary artery bypass graft with or without cardiopulmonary bypass. METHODS: From January 2001 to December 2005, 217 nonrandomized, consecutive, and nonselected patients with an ejection fraction less than or equal to 20 percent underwent coronary artery bypass graft surgery with (112) or without (off-pump) (105) the use of cardiopulmonary bypass. We studied demographic, operative, and postoperative data. RESULTS: There were no demographic differences between groups. The outcome variables showed similar graft numbers in both groups. Mortality was 12.5 percent in the cardiopulmonary bypass group and 3.8 percent in the off-pump group. Postoperative complications were statistically different (cardiopulmonary bypass versus off-pump): total length of hospital stay (days)-11.3 vs. 7.2, length of ICU stay (days)-3.7 vs. 2.1, pulmonary complications-10.7 percent vs. 2.8 percent, intubation time (hours)-22 vs. 10, postoperative bleeding (mL)-654 vs. 440, acute renal failure-8.9 percent vs. 1.9 percent and left-ventricle ejection fraction before discharge-22 percent vs. 29 percent. CONCLUSION: Coronary artery bypass grafting without cardiopulmonary bypass in selected patients with severe left ventricular dysfunction is valid and safe and promotes less mortality and morbidity compared with conventional operations.


Subject(s)
Aged , Female , Humans , Male , Coronary Artery Bypass, Off-Pump/methods , Ventricular Dysfunction, Left/surgery , Coronary Artery Bypass, Off-Pump/adverse effects , Severity of Illness Index , Treatment Outcome , Ventricular Dysfunction, Left/physiopathology
9.
Rev. bras. cir. cardiovasc ; 25(3): 293-302, jul.-set. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-564994

ABSTRACT

OBJETIVO: A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, levando à contraindicação do procedimento, apesar dos sintomas. O implante minimamente invasivo transcateter de valva aórtica parece ser uma alternativa, reduzindo a morbi-mortalidade. O objetivo deste estudo foi o desenvolvimento e implante de nova prótese para implante transcateter. MÉTODOS: Após desenvolvimento em animais, uma prótese transcateter, balão-expansível foi utilizada em 14 casos de alto risco. O EuroSCORE médio foi de 43,7 por cento. Quatro pacientes apresentavam disfunção de biopróteses e o restante, estenose aórtica calcificada. Todos os pacientes eram sintomáticos. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Com o uso de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência ou choque hemorrágico controlado, após valvoplastia aórtica. Foram realizados controles clínicos e ecocardiográficos seriados. RESULTADOS: A correta liberação da prótese foi possível em 13 casos. Uma conversão ocorreu. Não houve mortalidade operatória. O gradiente de pico médio pós-implante foi de 25 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual não significativa esteve presente em 71 por cento dos casos, nenhuma significativa. Não ocorreu complicação vascular periférica. Não houve necessidade de marcapasso definitivo. Um caso de acidente vascular cerebral ocorreu. A mortalidade geral foi de 42 por cento. CONCLUSÃO: O implante transapical de valva aórtica transcateter é um procedimento possível com esta nova prótese. O comportamento hemodinâmico foi satisfatório. São necessários estudos de longo prazo e com maior poder amostral, no intuito de determinar a real eficácia e indicação do procedimento alternativo.


OBJECTIVE: The aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such a risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for the aortic position implant. METHODS: After animal studies, 14 patients with high EuroSCORE underwent transcatheter aortic valve implantation. Median Logistic EuroSCORE was 43.7 percent. Four patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. All patients presented symptoms. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis was implanted through the ventricular apex under ventricular pacing or hemorrhagic shock, after aortic valvoplasty. Echocardiograph and angiograph controls were performed, and the patients were referred to ICU. RESULTS: Implant was feasible in 13 cases. There were no intra-operative deaths. Median peak transvalvular aortic gradient reduced to 25.0 mmHg, and left ventricular function improved in the first seven post-operative days. Paravalvular aortic regurgitation was mild and present in 71 percent. No definitive pacemaker was needed. There was no peripheral vascular complication. Overall mortality was 42 percent. CONCLUSION: The transapical implantation of cathetermounted bioprosthesis was a feasible procedure. Long term follow-up is mandatory in order to access efficacy and indications.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Thoracotomy/methods , Aortography , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/mortality , Treatment Outcome
10.
Arq. bras. cardiol ; 93(3): e45-e47, set. 2009. ilus
Article in English, Spanish, Portuguese | LILACS | ID: lil-529182

ABSTRACT

A cirurgia de revascularização do miocárdio (CRM) é um procedimento bem estabelecido com indicações atuais precisas. O advento e a disseminação dessa técnica foram possíveis após a introdução do angiograma coronário. Embora muitos métodos de avaliação tenham evoluído nos últimos anos, nenhum conseguiu substituir o angiograma coronário invasivo como exame pré-operatório. A tomografia computadorizada (TC) emergiu como uma alternativa ao angiograma coronário invasivo. O presente relato descreve dois casos de CRM realizadas usando-se apenas a TC como técnica de avaliação anatômica das artérias coronárias pré-operatória.


Coronary artery bypass graft (CABG) is a well established procedure with current precise indications. The advent and spread of this technique was possible after the introduction of the coronary angiogram. Although many evaluation methods have been developed in the past years, to date, none have been able to replace the invasive coronary angiogram as a pre-operative exam. Computed tomography angiography (CTA) has emerged as an alternative to invasive coronary angiogram. In this report we describe two CABG cases that were performed using only this technique as a pre-operative anatomic coronary arteries evaluation.


La cirugía de revascularización del miocardio (CRM) es un procedimiento bien establecido con indicaciones actuales precisas. El advenimiento y la divulgación de esta técnica fueron posibles después de la introducción del angiograma coronario. Aunque muchos métodos de evaluación hayan evolucionados en los últimos años, ninguno ha conseguido sustituir al angiograma coronario invasivo como examen preoperatorio. La tomografía computada (TC) surgió como una alternativa al angiograma coronario invasivo. El presente informe describe dos casos de CRM realizadas usando sólo la TC como técnica de evaluación anatómica de las arterias coronarias preoperatoria.


Subject(s)
Aged , Humans , Male , Middle Aged , Coronary Angiography/methods , Coronary Artery Bypass/methods , Coronary Stenosis , Tomography, X-Ray Computed/methods , Coronary Stenosis/surgery , Preoperative Care
11.
Rev. bras. cir. cardiovasc ; 24(2): 233-238, abr.-jun. 2009. ilus
Article in English, Portuguese | LILACS | ID: lil-525563

ABSTRACT

OBJETIVO: A troca valvar aórtica é procedimento rotineiro, envolve substituição da valva nativa/prótese. Na maioria destes pacientes o risco é aceitável, porém, em alguns casos, o risco predito pode justificar contra-indicação. O implante de valva aórtica minimamente invasivo transcateter e sem circulação extracorpórea (CEC) tem se mostrado viável, com menor morbi-mortalidade. O objetivo deste trabalho foi desenvolver bioprótese aórtica, montada em cateter, para implante sem CEC. MÉTODOS: Após desenvolvimento em animais, três pacientes com EuroSCORE elevado foram submetidos ao implante. Caso 1: portador de bioprótese com disfunção; Caso 2: estenose aórtica grave; Caso 3: disfunção de bioprótese aórtica. Após minitoracotomia e sob controle ecocardiográfico e fluoroscópico, cateter-balão foi posicionado sobre posição aórtica e insuflado. Após, segundo cateter-balão, com endoprótese valvada, foi posicionado e liberado sob alta frequência ventricular. Controles angiográficos e ecocardiográficos foram realizados e pacientes encaminhados para UTI. RESULTADOS: No primeiro caso foi possível implante sem CEC com resultados adequados. Evoluiu com melhora da função ventricular. Cursou com broncopneumonia, fístula traqueo-esofágica e óbito por mediastinite. Necropsia confirmou bom posicionamento valvar e preservação dos folhetos. O segundo caso apresentou migração do dispositivo após insuflação do balão, necessidade de esternotomia mediana de urgência, CEC e troca valvar convencional. O paciente evoluiu bem, recebendo alta da UTI 14 dias após procedimento e sem complicações. Cursou com infecção respiratória, choque séptico e óbito no 60º pós-operatório. O terceiro caso foi submetido a implante com sucesso. CONCLUSÃO: O implante de bioprótese transapical montada em cateter sem CEC mostrou ser procedimento factível. Detalhes técnicos e a curva de aprendizado demandam discussão.


OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible ...


Subject(s)
Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Valve Stenosis/therapy , Aortic Valve/surgery , Bioprosthesis , /instrumentation , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Cardiopulmonary Bypass , Fatal Outcome , Heart Valve Prosthesis Implantation/adverse effects , Prosthesis Design , Prosthesis Failure , Reoperation , Risk Assessment
12.
Rev. bras. cir. cardiovasc ; 24(1): 44-49, Jan.-Mar. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-515585

ABSTRACT

OBJETIVOS: Analisar a eficácia e a segurança da drenagem pericárdica videotoracoscópica no tratamento e diagnóstico etiológico dos derrames pericárdicos por meio da revisão de 26 casos. MÉTODOS: De abril de 2005 a dezembro de 2007, 26 pacientes com derrame pericárdico foram submetidos ao procedimento. A média etária foi de 48,2 anos. O sintoma mais comum foi dispnéia, seguida por dor torácica. O procedimento foi realizado em decúbito lateral, sob anestesia geral e intubação seletiva, com o auxílio de três trocateres. RESULTADOS: A realização do procedimento foi possível em 25 casos. Ocorreu uma conversão. Em 61,53 por cento dos casos, o procedimento foi capaz de alterar o diagnóstico inicial. Culturas e microbiologia foram negativas em todos os casos. Achados compatíveis com neoplasia estavam presentes em nove casos, tuberculose em dois, aspergilose em um, pós-cirúrgico em três, lúpico em dois, urêmico em um e oito idiopáticos. Em quatro casos, procedimentos pleuropulmonares concomitantes foram realizados. Não ocorreram óbitos relacionados ao procedimento. Ocorreu uma recidiva. CONCLUSÃO: O procedimento demonstrou ser seguro, reprodutível e eficaz, capaz de fornecer diagnóstico etiológico e mudar o curso terapêutico de alguns pacientes. O procedimento pode se tornar o padrão-ouro em doentes selecionados.


OBJECTIVES: To assess efficacy and safety of videothoracoscopic pericardial drainage in the treatment and diagnostic of pericardial effusion through 26 cases review. METHODS: From April 2005 to December 2007, 26 patients with pericardial effusion underwent a video-thoracoscopic pericardial window. Median age was 48.2 years old. Dyspnea was the most frequent symptom followed by thoracic pain. The procedure was performed in lateral decubitus, under general anesthesia and selective intubation with the aid of three trocars. RESULTS: Procedure accomplish was feasible in 25 cases. One conversion occurred. In 61.53 percent of the cases the procedure was able to modify the initial diagnosis. Microbiology and tissue culture were negative in all cases. Neoplasia was present in nine cases, tuberculosis in two, aspergillosis in one, postoperative heart surgeries in three; lupus in two, uremia in one and idiopathy in eight. Associated pleuropulmonary procedures were performed in four cases. No deaths related to the procedure occurred. One late recurrence was recorded. CONCLUSION: The procedure is feasible, safe, reproducible and allowed an etiologic diagnostic. Specific treatment could be initiated in some cases. The intervention could possibly be the new gold standard treatment of pericardial effusion in selected patients.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Drainage/methods , Pericardial Effusion/therapy , Thoracic Surgery, Video-Assisted/methods , Drainage/standards , Pericardial Effusion/diagnosis , Pericardial Effusion/etiology , Thoracic Surgery, Video-Assisted/standards , Young Adult
13.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 18(4): 403-408, out.-dez. 2008. ilus
Article in Portuguese | LILACS | ID: lil-504960

ABSTRACT

As intervenções aórticas possuem muitas décadas de evolução. Desde os relatos iniciais dos anos 50, diversas modificações...


Subject(s)
Humans , Aortic Valve Stenosis/complications , Aortic Valve/surgery , Risk Factors
14.
Rev. bras. cir. cardiovasc ; 23(3): 323-329, jul.-set. 2008. ilus
Article in English, Portuguese | LILACS | ID: lil-500516

ABSTRACT

OBJETIVO: O enxerto de veia safena (VS) utilizado em revascularização miocárdica possui uma vida útil, sendo o estágio final a oclusão do vaso. Esforços em adquirir novas técnicas de coleta da VS podem possibilitar uma viabilidade maior do enxerto. MÉTODOS: Vinte pacientes foram randomizados e divididos em dois grupos com o objetivo de avaliação do endotélio vascular. A técnica "no touch" (NT) consiste em retirar o segmento de VS com o tecido perivascular. A técnica convencional consiste em retirar a VS, com remoção "in situ" do tecido perivascular e conseqüente vasoespasmo. Houve um padrão de retirada das VS com incisões longitudinais escalonadas. Características da VS foram consideradas. A avaliação do endotélio das VS foi realizada usando microscópio eletrônico (ME) pelo método de varredura e de transmissão. Cortes histológicos das VS foram corados em Hematoxilina-Eosina (HE). O colágeno subendotelial foi analisado pelos métodos de Picro-Sirius e Tricrômio de Masson. RESULTADOS: A ME evidenciou que o Grupo NT possui maiores áreas endoteliais não desnudadas, além de um menor número de células degradadas. A coloração em HE nos permitiu verificar a forma e a integridade das camadas das VS. Há um predomínio maior de fibras colágenas coradas no Grupo NT. CONCLUSÕES: A técnica NT permite uma melhor preservação endotelial da VS, sugerindo um enxerto mais viável em longo prazo.


OBJECTIVE: Saphenous vein grafts (SV) used in coronary artery bypass grafting have a limited life and vein occlusion may be the final adverse effect. Efforts to develop new techniques to harvest the saphenous vein may improve the viability of the graft. METHODS: Twenty patients were randomly divided into two groups with the objective of evaluating the vascular endothelium. The No Touch (NT) technique consists in removing the saphenous vein with perivascular tissue. The conventional technique consists in harvesting with "in situ" removal of the perivascular tissue. The standard saphenous vein harvesting procedure used bridged incisions. Characteristics of the vein were considered. Evaluation of the endothelium was achieved by electron microscopy and histologic analysis using hematoxylin eosin staining. The Picrosirius and Masson Trichrome methods were used to analyze subendothelial collagen. RESULTS: Electron microscopy demonstrated that the NT Group had larger non-denudated endothelial areas as well as a smaller number of degraded cells. Histological analysis showed the form and integrity of the saphenous vein layers. A larger amount of collagen fibers were identified in the NT Group. CONCLUSIONS: The NT technique better preserves the saphenous vein endothelium suggesting a more viable graft in the long term.


Subject(s)
Humans , Collagen/ultrastructure , Coronary Artery Bypass/methods , Endothelium, Vascular/ultrastructure , Saphenous Vein/ultrastructure , Tissue and Organ Harvesting/methods , Azo Compounds , Coloring Agents , Eosine Yellowish-(YS) , Hematoxylin , Methyl Green , Saphenous Vein/cytology , Saphenous Vein/transplantation
15.
Rev. bras. cir. cardiovasc ; 23(3): 415-417, jul.-set. 2008. ilus
Article in Portuguese | LILACS | ID: lil-500530

ABSTRACT

A obesidade e as comorbidades desencadeadas ou agravadas pela mesma têm se tornado um problema de saúde pública. Diversas terapêuticas buscaram métodos capazes de reduzir de modo efetivo a massa dos indivíduos obesos e, conseqüentemente, atenuar as complicações a ela relacionadas. Dentre essas abordagens, nos últimos anos, os procedimentos bariátricos têm crescido de forma significativa, sendo capazes de promover reduções de massa expressivas e duradouras. Diversas complicações precoces e tardias são descritas e relacionadas aos procedimentos bariátricos restritivos e malabsortivos. Neste relato, descrevemos dois casos de complicações cardiovasculares (dissecção e aneurisma) no pósoperatório tardio de procedimentos bariátricos.


Obesity and its correlated comorbidities are nowadays considered a public health concern. In the last few years, a myriad of strategies searched an effective procedure to reduce weight and decreases related comorbidities. Among these strategies, the bariatric procedures have been achieved a significantly increase, being able to promote an expressive and lasting weight reduction. Diverse early and late complications are described and related to restrictive and malabsortive bariatric procedures. In this report we describe two cases of cardiovascular complications (aortic dissection and aneurysm) in the late postoperative period of the bariatric procedures.


Subject(s)
Humans , Male , Middle Aged , Aortic Dissection/etiology , Aortic Aneurysm/etiology , Bariatric Surgery/adverse effects , Aortic Dissection , Aortic Aneurysm , Postoperative Period
16.
Arq. bras. cardiol ; 91(2): e17-e19, ago. 2008. ilus
Article in English, Portuguese | LILACS | ID: lil-488903

ABSTRACT

A persistência do canal arterial (PCA) é uma anomalia relativamente freqüente e de simples correção. A correção envolve a ligadura do ducto com ou sem a sua secção. A anomalia em adultos pode provocar hipertensão pulmonar persistente e disfunção ventricular. A correção em adultos é controversa e de maior risco. Um caso de correção endovascular com acesso intra-abdominal da PCA em adulto é descrito.


The patent ductus arteriosus (PDA) is a common type of congenital heart defect and its correction is simple when performed early in life. Surgery is performed using stitches or clips. In adults, the anomaly can lead to pulmonary hypertension and ventricular dysfunction. Surgery in adults is controversial and high-risk. This report describes an alternative endovascular approach in an adult patient.


Subject(s)
Adult , Female , Humans , Ductus Arteriosus, Patent/surgery , Cardiac Catheterization/methods , Prosthesis Implantation/methods , Ductus Arteriosus, Patent/diagnosis , Treatment Outcome
17.
Rev. bras. cir. cardiovasc ; 18(3): 221-226, July-Sept. 2003. ilus, tab, graf
Article in English | LILACS | ID: lil-360615

ABSTRACT

INTRODUÇAO: A resposta inflamatória e os distúrbios metabólicos nas cirurgias de revascularizaçäo do miocárdio (RM) com e sem circulaçäo extracorpórea (CEC) têm sido pesquisados. A apoptose vem sendo estudada em modelos de isquemia, reperfusäo e processos crônicos. O objetivo deste trabalho é comparar o grau de apoptose detectada em cardiomiócitos, antes e após a RM com e sem CEC. MÉTODO: Dezoito indivíduos com indicaçäo de RM, divididos em dois grupos (CEC e OFF-PUMP), sendo o primeiro (CEC) com o emprego da CEC e o segundo sem o auxílio desta (OFF-PUMP), tiveram coletadas biópsias da aurícula direita, ao início e ao término da operaçäo. Os fragmentos foram submetidos à marcaçäo imunohistoquímica pelo método de TUNEL e à contagem das células em apoptose. RESULTADOS: Näo houve diferença entre os grupos nos dados cirúrgicos, demográficos e pós-operatórios. O número de pontes foi estatisticamente diferente. Näo houve diferença entre o número de células em apoptose nos grupos CEC e OFF-PUMP, ao início do procedimento. O número de células em apoptose näo apresentou diferença significante entre o início e o término do procedimento no grupo OFF-PUMP. O número de células em apoptose, ao início e ao término da operaçäo, no grupo CEC apresentou diferença significante. CONCLUSAO: O menor número de células em apoptose encontrado no grupo OFF-PUMP condiz com dados da literatura que sugerem que a CEC é uma agressäo à homeostase e capaz de gerar lesäo celular. Deste modo, mais um argumento favorável pode ser agregado para a maior indicaçäo de RM sem o uso de CEC.


Subject(s)
Humans , Apoptosis , Cardiopulmonary Bypass , Myocardial Revascularization , Extracorporeal Circulation
SELECTION OF CITATIONS
SEARCH DETAIL